Simcoe, On Contaminants: BTEX, F1-F4
In-situ bioremediation of soil and groundwater, completed in Summer
2008. MEEC successfully remediated the affected soils and groundwater
to satisfy Ontario Regulation 153/04 Table 1 (potable groundwater)
Standards
Project Value: $150,000
Wicksteed, On Contaminants: BTEX, F1-F4
Exsitu remediation of extensive petroleum impacts from former
aluminum smelter, in support of proposed industrial condo
redevelopment. On-going remediation of biopiles, with 75% of affected
soils shown to satisfy the remediation target of Ontario Regulation
153/04, Table 3 (Non-potable groundwater) Standards
Project Value: $1,700,000
Parry Sound, On Contaminants: BTEX, PHCs(F1-F4)
Exsitu bioremediation of underground petroleum storage tank system
at cartage facility in support of proposed project sale, with project
completion in May 2008. Successfully remediated the affected soils and
groundwater to satisfy Ontario Regulation 153/04 Table 1 (potable
groundwater) Standards.
Project Value: $100,000
|